Search results for "Experimental tests"
showing 10 items of 19 documents
Effects of confinement level, cross-section shape and corner radius on the cyclic behavior of CFRCM confined concrete columns
2014
Abstract The main results of an experimental research aiming to investigate the behavior of medium-size low-strength concrete columns wrapped with Carbon Fiber Reinforced Cementitious Matrix (CFRCM) under monotonic and cyclic compressive axial loads are presented. Thirty columns with circular, square and rectangular cross-sections were tested under monotonic and cyclic axial loads to investigate the effect of the confinement level, the cross-section shape and the corner radius on the stiffness, strength, and ductility of CFRCM confined concrete columns under cyclic loads. The results prove that CFRCM confining jackets provide substantial gain in compressive strength, deformability and absor…
Strength and ductility of confined concrete columns under axial load and biaxial bending
2012
The behaviour of prismatic reinforced concrete columns under increasing eccentric compression load was experimentally investigated and analytically modelled. Columns with distributed longitudinal reinforcement and closely spaced transverse reinforcement were tested up to failure, considering different values and directions of eccentricity. Preliminary tests were carried out under concentric compression in order to validate the choice of the stress-strain laws adopted for the confined concrete and the longitudinal steel bars in compression. In the paper, closed form expressions able to approximate the experimental results in the case of uniaxial bending are presented. Finally, a fibre numeri…
Analisi Sperimentale del Comportamento Ciclico di Elementi in Calcestruzzo a Bassa Resistenza Confinati con FRCM
2013
Vengono riportati i principali risultati di una campagna sperimentale finalizzata alla caratterizzazione della risposta sotto carichi assiali ciclici di colonne di calcestruzzo a bassa resistenza con sezione circolare, quadrata e rettangolare, rinforzate con fibre di carbonio immerse in matrice cementizia (CFRCM). Sono state condotte prove di compressione assiale su 30 campioni di altezza 600 mm, 10 a sezione cilindrica di diametro 300 mm, 10 quadrata di lato 200 mm, e 10 rettangolare di lato 200x400 mm. Le prove sono finalizzate a indagare gli effetti del carico ciclico, della forma della sezione, del raggio di curvatura degli spigoli e del numero di strati di tessuto di rinforzo sul legam…
Structural performances of pultruded GFRP emergency structures – Part 1: Experimental characterization of materials and substructure
2019
Abstract This paper presents an experimental study in the field of structures made of pultruded fiber reinforced polymers (FRP) elements to be used for emergency purposes. A preliminary design of a 3D pultruded glass fiber reinforced polymer structure is presented with the mechanical characterization of the constituting elements. The axial and flexural properties of laminate and I-shaped GRFP profiles are discussed considering the short term creep. In a companion paper, the benefits, the limits and the reliability of the structure analyzed for emergency applications are discussed. In details, the numerical structural analysis of the full-scale 3D model is described followed by the experimen…
Indagine sperimentale sul comportamento di pareti sismiche in acciaio sottoposte a taglio
2005
The paper concerns the experimental results performed on steel (S 235) zinc plated panels having 1500 x 1150 x 1.5 mm dimensions, linked to hinged steel frame. In order to the slenderness of plates, considerable displacements out-of-plane are evident at loads significantly lower of ultimate load. Considering the steel constitutive curves obtained from tensile tests, the comparison of experimental and numerical (ADINA) results is proposed. The results show the excellent seismic behaviour of the system having stable hysteresis loops.
Spin alignment and violation of the OZI rule in exclusive ω and ϕ production in pp collisions
2014
Exclusive production of the isoscalar vector mesons $\omega$ and $\phi$ is measured with a 190 GeV$/c$ proton beam impinging on a liquid hydrogen target. Cross section ratios are determined in three intervals of the Feynman variable $x_{F}$ of the fast proton. A significant violation of the OZI rule is found, confirming earlier findings. Its kinematic dependence on $x_{F}$ and on the invariant mass $M_{p\mathrm{V}}$ of the system formed by fast proton $p_\mathrm{fast}$ and vector meson $V$ is discussed in terms of diffractive production of $p_\mathrm{fast}V$ resonances in competition with central production. The measurement of the spin density matrix element $\rho_{00}$ of the vector mesons…
Strategies of Identification of a Base-Isolated Hospital Building by Coupled Quasi-Static and Snap-Back Tests
2020
In this paper, the description of a series of quasi-static pushing tests and dynamic snap-back tests is proposed, involving the base-isolated emergency building of the Palermo university hospital. The base isolation system is characterized by a set of double-curved friction pendulum isolators placed on the top of the columns of the underground level, characteristics that cannot be found in the experimental studies available in the literature. The aim of the work was to investigate the static and dynamic properties of the building in question and comparing the in-situ results with the characteristics assigned during the design process and to assess the level of agreement. Static lateral push…
Indagine sperimentale sul comportamento ciclico di pannelli sottili di controvento di telai in acciaio
2007
The paper concerns the experimental results performed on steel (S 235) zinc plated panels having 1500 x 1150 x 1.5 mm dimensions, linked to hinged steel frame. In order to the slen-derness of plates, considerable displacements out-of-plane are evident at loads significantly lower of ultimate load. Considering the steel constitutive curves obtained from tensile tests, the comparison of experimental and numerical (ADINA) results is proposed. The results show the excellent seismic behaviour of the system having stable hysteresis loops.
Prompt Determination of the Mechanical Properties of Industrial Polypropylene Sandwich Pipes
2021
A simple and prompt method to determine the mechanical properties of industrial multilayer extrusion polypropylene pipes for a gravity sewer network is suggested. The engineering formulas included for calculating the permissible thickness and relative position of a foam core in the pipes are based on a linear-elastic approximation and the rule of mixtures. The applicability of the approximation was justified experimentally during investigation of the effective tensile characteristics of single- and multilayer pipes and each layer specimen by using traditional tests and finite-element calculations. The results obtained were used to formulate engineering recommendations for calculations of th…
Full scale tests of the base-isolation system for an emergency hospital
2019
The paper presents the results of some full-scale tests regarding the base-isolation system of the emergency room building of the polyclinic hospital in Palermo (Italy). This building has been recently realized and its base isolation system is characterized by double friction pendulum isolators. Static lateral pushing tests were aimed at identifying fundamental mechanical properties of the whole isolation level (e.g. friction forces and stiffness) in order to verify the agreement with the design hypotheses. Further dynamic tests provided different displacements of the isolated base followed by the instantaneous release (snap-back tests), in order to verify the effectiveness, the mechanical …